To become the stage of realizing dreams of our employees! To build a happier, much more united and far more professional team! To reach a mutual profit of our clients, suppliers, the society and ourselves for Uf Filtration , Ultrafiltration In Wastewater Treatment , Ro Uf Filter , We have now confident that we can easily offer the premium quality products and solutions at resonable price, good after-sales services into the buyers. And we're going to produce a dazzling future.
Good Wholesale Vendors Hollow Fiber Membrane Water Filter - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo Detail:
Applications
Production of mineral water, spring water, or other sterile liquid.
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient |
Effect |
SS, Particles > 1μm |
Removal Rate ≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
> 4 log |
Turbidity |
<0. 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU. This product is qualified for drinking water related products.
Product Parameters
Technical Parameters
Filtering Type |
Inside-out |
Membrane Material |
Modified PVC |
MWCO |
100K Dalton |
Membrane Area |
3.8m2 |
Membrane ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ90mm*1016mm |
Connector Size |
Φ19mm |
Application Data
Pure Water Flux |
1,200L/H (0.15MPa, 25C) |
Designed Flux |
35-100L/m2.hr (0.15MPa, 25C) |
Suggested Working Pressure |
≤ 0.2MPa |
Maximum Transmembrane Pressure |
0.2MPa |
Maximum Working Temperature |
45C |
PH Range |
Working: 4-10; Washing: 2-12 |
Operating Mode |
Cross-flow or Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil & Grease |
≤ 2mg/L |
SS |
≤ 20mg/L |
Total Iron |
≤ 1mg/L |
Continuous Residual Chlorine |
≤ 5ppm |
COD |
Suggested ≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum Backwashing Pressure |
0.2MPa |
Backwashing Flow Rate |
100-150L/m2.hr |
Backwashing Frequency |
Every 30-60min. |
Backwashing Duration |
30-60s |
CEB Frequency |
0-4 times per day |
CEB Duration |
5-10min. |
CIP Frequency |
Every 1-3 months |
Washing Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic Pollution Washing |
0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic Pollution Washing |
1-2% Citric Acid/0.2% Hydrochloric Acid |
Component Material
Component |
Material |
Membrane |
Modified PVC |
Sealing |
Epoxy Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for Good Wholesale Vendors Hollow Fiber Membrane Water Filter - UF Membrane Module PVC Ultrafiltration Membrane Module UFc4040 RO housing – Bangmo , The product will supply to all over the world, such as: Saudi Arabia, London, Honduras, Upon today, we've customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the high quality products with lower price. We've been looking forward to doing business with you.