Submerged PVDF - MCR Out - In Single - Row Rack – BM-SLMRC-20m²
Submerged PVDF - MCR Out - In Single - Row Rack – BM-SLMRC-20m²
MCR RACK SPECIFICATIONS
|
Parameter |
Details |
|
Module Operating Process |
Submerged Membrane Module |
|
Application |
Membrane Chemical Reactor (MCR) |
|
Membrane Module Type |
BM-SLMCR-20m2 Hollow Fibre Membrane Filtration Modules (refer to separate specification sheets) |
|
Filtration Flow Direction |
Outside to Inside |
|
Backwash Type |
Relaxation |
|
Number of Membrane Modules Fitted |
Typically from 5 to 20 x 20m2 Membrane Filtration Modules in a single row . (Quantity can be customized ) |
|
Membrane Material |
PVDF (Polyvinylidene Fluoride) |
|
Nominal Membrane Pore Size |
0.03 μm |
|
Nominal Total Membrane Area (examples) |
5 Modules 100 m2 / 1,076 ft2 10 Modules 200 m2 / 2,153 ft 2 15 Modules 300 m2 / 3,229 ft2 20 Modules 400 m2 / 4,306 ft2 |
Parameter Details
|
Process Connection Options (Refer to End Connection Detail drawing for option details) |
Filtrate Outlet (all Grey PVC): Standard Dn50 Flange(JIS) Pipe Stub Dn50 Plain Pipe Stub Aeration Air Inlet (all Grey PVC): Standard Dn50 Flange(JIS) Pipe Stub Dn50 Plain Pipe Stub |
|||||||||||||
|
Aeration and Filtrate Termination Point Connection hardware |
Filtrate Outlet and Air Inlet hoses and quick coupling are not included but can be supplied as options to suit site requirements (length and connection types to be specified) |
|||||||||||||
|
Nominal Rack Assembly Width and Height |
865 mm W x 1960 mm H 34.055 in W x 77.165 in H |
|||||||||||||
|
Nominal Standard Rack Assembly Lengths Refer to General Arrangement Drawings for additional details. (Note: Blanking Kits available to reduce initial number of installed Modules per rack) |
Overall Length
|
|||||||||||||
|
Approximate Dual Rack Assembly Masses (loaded with Modules and filtrate side substantially filled with water) |
5P-20C 125 kg / 275.6 lbs 15P-20C 250 kg / 551.6 lbs 20P-20C 310 kg / 683.4 lbs (The mass will be greater if the Modules are heavily soiled) |
|||||||||||||
|
Recommended Minimum Hoist Capacity |
1000 kg / 2205 lbs |
|||||||||||||
|
Temperature Range for Transportation and Storage (without Modules) |
> 0 to50℃ / > 32 to 122 °F (Must not be exposed to freezing conditions) |
|||||||||||||
|
Protection from ultraviolet (UV) radiation |
The assembly should not be exposed to ultraviolet radiation (direct sunlight) during storage or operation. |
|||||||||||||


Send Email
Facebook
Twitter
Linkedin
Youtube