Submerged PVDF - MCR Out - In Double - Row Rack – BM-SLMCR-20m²
Submerged PVDF - MCR Out - In Double - Row Rack – BM-SLMCR-20m²
MCR RACK SPECIFICATIONS
|
Parameter |
Details |
|
Module Operating Process |
Submerged Membrane Module |
|
Application |
Membrane Chemical Reactor (MCR) |
|
Membrane Module Type |
BM-SLMCR-20m2 Hollow Fibre Membrane Filtration Modules (refer to separate specification sheets) |
|
Filtration Flow Direction |
Outside to Inside |
|
Backwash Type |
Relaxation |
|
Number of Membrane Modules Fitted |
Typically from 26 to 40 x 20m2 Membrane Filtration Modules in a single row . (Quantity can be customized ) |
|
Membrane Material |
PVDF (Polyvinylidene Fluoride) |
|
Nominal Membrane Pore Size |
0.03 μm |
|
Nominal Total Membrane Area (examples) |
26 Modules 520 m2 / 5,597 ft2 30 Modules 600 m2 / 6,458 ft 2 36 Modules 720 m2 / 7,750 ft2 40 Modules 800 m2 / 8,611 ft2 |
Parameter Details
|
Process Connection Options (Refer to End Connection Detail drawing for option details) |
Filtrate Outlet (all Grey PVC): Standard Dn65/Dn80 Flange(JIS) Pipe Stub Dn65/Dn80 Plain Pipe Stub Aeration Air Inlet (all Grey PVC): Standard Dn65/Dn80 Flange(JIS) Pipe Stub Dn65/Dn80 Plain Pipe Stub |
|||||||||||||
|
Aeration and Filtrate Termination Point Connection hardware |
Filtrate Outlet and Air Inlet hoses and quick coupling are not included but can be supplied as options to suit site requirements (length and connection types to be specified) |
|||||||||||||
|
Nominal Rack Assembly Width and Height |
1630 mm W x 1960 mm H 64.173 in W x 77.165 in H |
|||||||||||||
|
Nominal Standard Rack Assembly Lengths Refer to General Arrangement Drawings for additional details. (Note: Blanking Kits available to reduce initial number of installed Modules per rack) |
Overall Length
|
|||||||||||||
|
Approximate Dual Rack Assembly Masses (loaded with Modules and filtrate side substantially filled with water) |
380 kg /837.6 lbs 430 kg /947.9 lbs 550 kg / 1,212.5 lbs 26P-20C 36P-20C (The mass will be greater if the Modules are heavily soiled) |
|||||||||||||
|
Recommended Minimum Hoist Capacity |
2000 kg / 4409 lbs |
|||||||||||||
|
Temperature Range for Transportation and Storage (without Modules) |
> 0 to50℃ / > 32 to 122 °F (Must not be exposed to freezing conditions) |
|||||||||||||
|
Protection from ultraviolet (UV) radiation |
The assembly should not be exposed to ultraviolet radiation (direct sunlight) during storage or operation. |
|||||||||||||


Send Email
Facebook
Twitter
Linkedin
Youtube